Index Diana Palmer Long Tall Texans 32 Boss Man Loius L'Amour Trail to Crazy Man Man's Supreme Inheritance by F.M.Alexander Man Outs Ian Fleming Bond 05 (1957) From Russia With Love McGahern John Miedzy niewiastami Bodil_Malmsten_ _Moje_pierwsze_zycie Conrad Linda Pasja i namić™tnośÂ›ć‡ Rice Anne The Vampire Lestat [en] Hegel The Phemenology of Mind |
[ Pobierz caÅ‚ość w formacie PDF ] Ò! Solenoid valve, raising/relieving lifting/trailing axle.........................................................44 Ò! ALB control......................................................................................................................45 Ò! Solenoid valve, front axle ................................................................................................46 Ò! Solenoid valve, dampers soft ..........................................................................................47 Ò! Solenoid valve, dampers medium ...................................................................................48 Plausibility fault (mechanical fault) during raising: Ò! Displacement sensor RR.................................................................................................50 Ò! Displacement sensor RL .................................................................................................51 Ò! Displacement sensor, front..............................................................................................52 Plausibility fault (mechanical fault) during lowering: Ò! Displacement sensor RR.................................................................................................60 Ò! Displacement sensor RL .................................................................................................61 Ò! Displacement sensor, front..............................................................................................62 Control unit defective ...........................................................................................................80 Speed signals, interruption or short-circuit to +UB...............................................................81 SD 206-2.97 Page 30 of 62 WEBASTO auxiliary heater Airtop 2000 Reading out the fault memory - The fault is shown automatically in the display when it occurs. The faults are shown in the display of the control box. Only one fault can be displayed. If more than one fault is present, the next fault will not be shown in the display until after the first fault has been rectified. Erasing the fault memory - After repairs switch off the heater, wait for after-running and switch heater on again. The fault will be erased automatically. Type of fault Flashcode No start, after 2 attempts to start...................................................................................... F 01 Flame interrupted, more than 5x within one heating cycle ............................................... F 02 Under/overvoltage............................................................................................................ F 03 Premature flame recognition............................................................................................ F 04 Flame monitor, interruption or short-circuit ...................................................................... F 05 Temperature sensor for heater, interruption or short-circuit............................................. F 06 Metering pump, short-circuit............................................................................................. F 07 Blower motor, interruption/short-circuit or defective speed.............................................. F 08 Glow plug, interruption or short-circuit ............................................................................. F 09 Overheating...................................................................................................................... F 10 SD 206-2.97 Page 31 of 62 Eberspächer auxiliary heater D1LCC/D3LCC Reading out the fault memory - Switch off the auxiliary heater - Switch on auxiliary heater with button . - Press button and with 2 seconds also press button . The last fault to occur will be shown in the display, e.g.: AF:64 With buttons and a further four faults, if present, can be read out. E.g.: F:10, F:13. Erasing the fault memory - Switch off the auxiliary heater- - Switch on auxiliary heater with button . - Press button and within 2 seconds also press button . - Open the 1-pole plug connection X 683, which is at the plug connection between wiring harness and control box. - Press buttons and simultaneously and close plug connection X 683. Type of fault Fault code No fault present............................................................................................................... (0)00 Control unit, chamber 1, to relay for fresh-air blower, short-circuit to earth or control unit defective...................................................................................... (0)04 Control unit, chamber 2, to relay for electrical isolator switch or input for anti-theft system, short-circuit to earth or control unit defective...................................... (0)05 TRS switch-off due to signal change from plus to minus at control unit, chamber 10, or plus at control unit, chamber 12............................................................. (0)09 Voltage between control unit chamber 5 and chamber 11: Ò! Overvoltage > 31.8 V (30.4 V if glow plug switched on)............................................. (0)10 Ò! Undervoltage Connection between control unit and overheating sensor: no continuity......................... (0)12 Overtemperature in flame sensor > 340° C or > 2270 &! ............................................... (0)13 To many overheatings, control unit locked...................................................................... (0)15 Check glow plug (approx. 1 &! to 2 &!), control units chambers 6 and 9 to glow plug, interruption or control unit defective........................................................... (0)20 Glow plug or control unit, chamber 6, to glow plug: short-circuit or control unit defective................................................................................................... (0)21 If the fault code is read out with an Eberspächer diagnosis unit, it has 3 digits (e.g. 021). If it is read out with the module clock, it has only 2 digits (e.g. 21). SD 206-2.97 Page 32 of 62 Type of fault Fault code Control unit, chamber 4, to connection plug for module clock: short-circuit to plus.......................................................................................................... (0)25 Burner motor or speed control defective: speed discrepancy ......................................... (0)33 Metering pump or control unit, chamber 3, to metering pump: Ò! Short-circuit ................................................................................................................ (0)47 Ò! No continuity, check minus supply for metering pump ............................................... (0)48 Too many attempts to start, control unit locked .............................................................. (0)50 Flame already present at switch-on (flame sensor > 62° or >1240 &!)............................ (0)51 [ Pobierz caÅ‚ość w formacie PDF ] |
||||
Wszelkie Prawa Zastrzeżone! Lubię Cię. Bardzo. A jeszcze bardziej się cieszę, że mogę Cię lubić. Design by SZABLONY.maniak.pl. | |||||